General specifications XTCE050D00AProduct NameEaton Moeller® series DILM contactorCatalog Number277827Model CodeDILM50(110V50HZ,120V60HZ)EAN4015082778279Product Length/Depth132.1 mmProduct Height115 mmProduct Width55 mmProduct Weight0.872 kgCertificationsIEC/EN 60947-4-1
UL 60947-4-1
UL Category Control No.: NLDX
CSA Class No.: 2411-03, 3211-04
IEC/EN 60947
VDE 0660
CE
UL
CSA File No.: 012528
CSA-C22.2 No. 60947-4-1-14
UL File No.: E29096
CSACatalog NotesContacts according to EN 50012Product specificationsNumber of polesThree-pole10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.2 Corrosion resistanceMeets the product standard's requirements.10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.2.7 InscriptionsMeets the product standard's requirements.10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distancesMeets the product standard's requirements.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.10.8 Connections for external conductorsIs the panel builder's responsibility.10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.10.9.3 Impulse withstand voltageIs the panel builder's responsibility.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Operating frequency5000 mechanical Operations/h (AC operated)Pollution degree3Climatic proofingDamp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78Connection to SmartWire-DTNoRated impulse withstand voltage (Uimp)8000 V ACUtilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-3: Normal AC induction motors: starting, switch off during runningConnectionScrew terminalsFrame sizeFS3Ambient operating temperature - max60 °CAmbient operating temperature - min-25 °CAmbient operating temperature (enclosed) - max40 °CAmbient operating temperature (enclosed) - min25 °CAmbient storage temperature - max80 °CAmbient storage temperature - min40 °CAssigned motor power at 115/120 V, 60 Hz, 1-phase3 HPAssigned motor power at 200/208 V, 60 Hz, 3-phase15 HPAssigned motor power at 230/240 V, 60 Hz, 1-phase10 HPAssigned motor power at 230/240 V, 60 Hz, 3-phase20 HPAssigned motor power at 460/480 V, 60 Hz, 3-phase40 HPAssigned motor power at 575/600 V, 60 Hz, 3-phase50 HPConventional thermal current ith (1-pole, enclosed)145 AConventional thermal current ith (3-pole, enclosed)58 AConventional thermal current ith at 55°C (3-pole, open)68 AConventional thermal current ith of main contacts (1-pole, open)162 AEquipment heat dissipation, current-dependent Pvid9.9 WHeat dissipation capacity Pdiss0 WHeat dissipation per pole, current-dependent Pvid3.3 WApplicationContactors for MotorsProduct categoryContactorsProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)Arcing time10 msElectrical connection type of main circuitScrew connectionScrewdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
2, Terminal screw, Pozidriv screwdriverVoltage typeACDegree of protectionIP00Number of auxiliary contacts (normally closed contacts)0Number of auxiliary contacts (normally open contacts)0Number of contacts (normally closed) as main contact0Number of main contacts (normally open contact)3Rated breaking capacity at 220/230 V500 ARated breaking capacity at 380/400 V500 ARated breaking capacity at 500 V500 ARated breaking capacity at 660/690 V320 ARated control supply voltage (Us) at AC, 50 Hz - max110 VRated control supply voltage (Us) at AC, 50 Hz - min110 VRated control supply voltage (Us) at AC, 60 Hz - max120 VRated control supply voltage (Us) at AC, 60 Hz - min120 VDrop-out voltageAC operated: 0.6 - 0.3 x UC, AC operatedOvervoltage categoryIIIDuty factor100 %Emitted interferenceAccording to EN 60947-1Interference immunityAccording to EN 60947-1Lifespan, mechanical10,000,000 Operations (AC operated)Pick-up voltage0.8 - 1.1 V AC x UcPower consumption, pick-up, 50 Hz149 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 HzSafe isolation440 V AC, Between the contacts, According to EN 61140
440 V AC, Between coil and contacts, According to EN 61140Power consumption, pick-up, 60 Hz178 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 HzScrew sizeM3.5, Terminal screw, Control circuit cables
M6, Terminal screw, Main cablesPower consumption, sealing, 50 Hz4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
16 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 HzPower consumption, sealing, 60 Hz19 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 HzTerminal capacity (stranded)2 x (16 - 35) mm², Main cables
1 x (16 - 50) mm², Main cablesTerminal capacity (copper band)2 x (6 x 9 x 0.8) mm (Number of segments x width x thickness), Main cablesTerminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 25) mm², Main cables
1 x (0.75 - 35) mm², Main cablesShock resistance10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 msTerminal capacity (solid)2 x (0.75 - 16) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 4) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cablesTerminal capacity (solid/stranded AWG)18 - 14, Control circuit cables
Single 14 - 1, double 14 - 2, Main cablesSwitching capacity (main contacts, general use)80 A, Maximum motor rating (UL/CSA)Tightening torque3.3 Nm, Screw terminals, Main cables
1.2 Nm, Screw terminals, Control circuit cablesRated control supply voltage (Us) at DC - max0 VRated control supply voltage (Us) at DC - min0 VRated insulation voltage (Ui)690 VRated making capacity up to 690 V (cos phi to IEC/EN 60947)700 ARated operational current (Ie) at AC-1, 380 V, 400 V, 415 V80 ARated operational current (Ie) at AC-3, 220 V, 230 V, 240 V50 ARated operational current (Ie) at AC-3, 380 V, 400 V, 415 V50 ARated operational current (Ie) at AC-3, 440 V50 ARated operational current (Ie) at AC-3, 500 V50 ARated operational current (Ie) at AC-3, 660 V, 690 V32 ARated operational current (Ie) at AC-4, 220 V, 230 V, 240 V21 ARated operational current (Ie) at AC-4, 400 V21 ARated operational current (Ie) at AC-4, 440 V21 ARated operational current (Ie) at AC-4, 500 V21 ARated operational current (Ie) at AC-4, 660 V, 690 V17 ARated operational current (Ie) at DC-1, 110 V50 ARated operational current (Ie) at DC-1, 220 V45 ARated operational current (Ie) at DC-1, 60 V60 ARated operational current for specified heat dissipation (In)50 ARated operational power at AC-3, 240 V, 50 Hz17 kWRated operational power at AC-3, 380/400 V, 50 Hz22 kWRated operational power at AC-3, 415 V, 50 Hz30 kWRated operational power at AC-4, 220/230 V, 50 Hz6 kWRated operational power at AC-4, 240 V, 50 Hz6.5 kWRated operational power at AC-4, 380/400 V, 50 Hz10 kWRated operational power at AC-4, 415 V, 50 Hz11 kWRated operational power at AC-4, 440 V, 50 Hz12 kWRated operational power at AC-4, 500 V, 50 Hz13 kWRated operational power at AC-4, 660/690 V, 50 Hz14 kWRated operational power (NEMA)29.8 kWRated operational voltage (Ue) at AC - max690 VResistance per pole1.9 mΩStatic heat dissipation, non-current-dependent Pvs4.1 WStripping length (control circuit cable)10 mmStripping length (main cable)14 mmSwitching time (AC operated, make contacts, closing delay) - max18 msSwitching time (AC operated, make contacts, closing delay) - min12 msSwitching time (AC operated, make contacts, opening delay) - max13 msSwitching time (AC operated, make contacts, opening delay) - min8 msShort-circuit current rating (basic rating)250 A, max. CB, SCCR (UL/CSA)
250 A, max. Fuse, SCCR (UL/CSA)
10 kA, SCCR (UL/CSA)Short-circuit current rating (high fault at 480 V)30/100 kA, Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
100 A, max. CB, SCCR (UL/CSA)Short-circuit current rating (high fault at 600 V)30/100 kA, Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)Short-circuit protection rating (type 1 coordination) at 400 V160 A gG/gLSuitable forAlso motors with efficiency class IE3Short-circuit protection rating (type 1 coordination) at 690 V80 A gG/gLShort-circuit protection rating (type 2 coordination) at 400 V80 A gG/gLShort-circuit protection rating (type 2 coordination) at 690 V63 A gG/gLSpecial purpose rating of ballast electrical discharge lamps79 A (600V 60Hz 3phase, 347V 60Hz 1phase)
79 A (480V 60Hz 3phase, 277V 60Hz 1phase)Special purpose rating of elevator control40 HP, 600 V 60 Hz 3-ph, (UL/CSA)
32.2 A, 200 V 60 Hz 3-ph, (UL/CSA)
15 HP, 240 V 60 Hz 3-ph, (UL/CSA)
10 HP, 200 V 60 Hz 3-ph, (UL/CSA)
42 A, 240 V 60 Hz 3-ph, (UL/CSA)
40 A, 480 V 60 Hz 3-ph, (UL/CSA)
41 A, 600 V 60 Hz 3-ph, (UL/CSA)
30 HP, 480 V 60 Hz 3-ph, (UL/CSA)Special purpose rating of resistance air heating79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
79 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)Special purpose rating of tungsten incandescent lamps74 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)Conventional thermal current ith at 40°C (3-pole, open)80 AConventional thermal current ith at 50°C (3-pole, open)71 AConventional thermal current ith at 60°C (3-pole, open)65 ARated operational power at AC-3, 440 V, 50 Hz32 kWRated operational power at AC-3, 500 V, 50 Hz36 kWRated operational power at AC-3, 690 V, 50 Hz30 kWActuating voltage110 V 50 Hz, 120 V 60 HzAltitudeMax. 2000 mOperating voltage at AC, 50 Hz - min230 VOperating voltage at AC, 50 Hz - max690 VOperating voltage at AC, 60 Hz - min230 VOperating voltage at AC, 60 Hz - max690 V